Trip Units Part 1
Pow-R-Line C Group Mounted Switchboards feature a standardized, cost effective design that makes them easy to install and maintain. They utilize the full family of Cutler-Hammer molded case circuit breakers and fusible switches.
Design capabilities are enhanced by the wide range of available main devices, utility provisions, and customer metering arrangements.
|
Customer Metering
- Full family of IQ metering and protective devices available.
- Conventional meters and switches available.
|
|
Utility Metering
- Built to specific utility requirements for all service areas.
|
|
Main Devices, Individually Mounted
- Series C Breaker; 400-2,500 amperes, fixed mounted or drawout.
- Insulated Case Power Breaker; SPB, 800-5,000 amperes, fixed mounted.
- Insulated Case Power Breaker; SPB, 800-4,000 amperes, drawout.
- Power Circuit Breaker; DSII/DSLII, 800-4,000 amperes, fixed mounted or drawout.
- Digitrip RMS 310, 510, 610, 810, 910, and OPTIM 750 and 1050 Trip Units available.
- Bolted pressure contact switch; 800-6,000 amperes, fixed mounted.
- Fusible switches; FDPW, 400-1,200 amperes, fixed mounted.
- Main lugs only; mechanical or compression, 400-6,000 amperes.
- Incoming busway or transformer connection available.
|
|
Feeder Devices, Compartmentalized
- Series C Breaker; 15-1,200 amperes.
- Digitrip RMS 310, OPTIM 750, and OPTIM 1050 Trip Units available.
- Fusible switches; FDPW, 30-1,200 amperes.
- Ability to mix circuit breakers and fusible switches.
- Optional 11X compartment for customer mounted devices available.
- Optional customer metering available; maximum 38X space.
|
Back to top of page.
Trip Units Part 2
![one](images/2one.gif) |
Branch wiring gutters.
|
![two](images/2two.gif) |
Optional hinged gutter covers to provide easy access to branch wiring.
|
![three](images/2tthree.gif) |
Unique chassis design accommodates a variety of Cutler-Hammer breakers, trip units, and accessories.
|
![four](images/2four.gif) |
Fully rated cross bus (never tapered) is predrilled to accept future Pow-R-Line C sections.
|
![five](images/2five.gif) |
Optional IQ Energy Sentinel mounted on a K-frame breaker. This device allows the customer to monitor energy usage (kWh) through a BIM, IMPACC, or a personal computer. IQ Energy Sentinels are available on standard F-, J-, or K-frame breakers.
|
![six](images/2six.gif) |
Ability to twin mount K-frame (400 ampere) breakers.
|
![seven](images/2seven.gif) |
L-frame breaker with a Digitrip OPTIM 1050 Trip Unit factory wired for communications, ground fault, energy monitoring, and harmonics monitoring.
|
![eight](images/2eight.gif) |
All OPTIM Trip Unit wiring is marked and securely bound with wire ties and accessible for customer inspection. The Cutler-Hammer reputation for quality and attention to detail is typified by the wiring, consistently characterized as "superior."
|
Back to top of page.
Optional Features for Trip Units
![Hinged Gutter Covers](images/swi022.gif) |
Optional hinged gutter covers to provide easy access to branch wiring. |
Five L- or N-frame breakers with Digitrip OPTIM Trip Units and one Breaker Interface Module can be mounted in a single 45-inch (1143.00-mm) wide distribution structure. Six L- or N-frame breakers can be mounted when the Breaker Interface Module is mounted in another section or is not required. |
![Five L- or N-Frame Breakers](images/swi023.gif) |
![Digitrip OPTIM Trip Units](images/swi024.gif) |
Digitrip OPTIM Trip Units can be easily programmed and monitored at the switchboard using the Breaker Interface Module. A hinged compartment houses the BIM and a 30 V Dc power supply for communications capability. For OPTIM 1050 Trip Units, a potential transformer module is supplied to provide voltage for power and energy monitoring. |
|
|