Superior rms Sensing for Accuracy and Reliability

OPTIM Trip Units Digitrip OPTIM Trip Units utilize the proprietary SuRE Plus™ Chip microprocessor that provides unparalleled accuracy for protection, system diagnostics, monitoring, and communications.

OPTIM technology builds upon the original, front adjustable Digitrip RMS Trip Units to provide high reliability and increased functionality to meet the sophisticated demands of today's and tomor-row's electrical distribution systems.

Content: Back to top of page.


Digitrip OPTIM 750 Features:

OPTIM 750
Digitrip OPTIM 750 Features:
  • rms Sensing
  • Programmable
  • 10 Curve Shaping Adjustments
  • Load Monitoring
  • Diagnostics
  • Communications
Back to the contents


RMS 510
Digitrip OPTIM 1050 Features:
  • rms Sensing
  • Programmable
  • 10 Curve Shaping Adjustments
  • Load Monitoring
  • Diagnostics
  • Communications
  • Power and Energy Monitoring
  • Harmonics

Back to top of page.


Trip Unit Monitoring

Programming and Monitoring Methods

Programming and trip unit monitoring can be completed at the trip unit with the hand held OPTIMizer while the Breaker Interface Module provides programming and monitoring at the assembly. With IMPACC Communications, programming and monitoring can be accomplish-ed remotely from a personal computer.
Trip Unit Monitoring

Trip Unit Monitoring
Back to top of page.


Protection and Coordination

Programmability Increases Protection and Coordination Capabilities

Protection and Coordination
Protection and Coordination
Provides Data to Improve Power Systems Reliability

Virtual Infinite Settings
Setting increments are increased by a factor of 10 as compared with conventional front adjustable trip units.

Improved Accuracy and Reliability
Time-current pick-up setpoints are shown in actual amperes, not multiples. True rms sensing prevents nuisance trips caused by non-sinusoidal waveforms.

System Security
Programmable password protection

Thermal Memory
Selectable powered and unpowered thermal memory prevents cumulative overheating due to repeated overloads, eliminating nuisance trips.

Selectable Sure Start Discriminator
Provides protection when closing a breaker on startup if no instantaneous setting has been programmed.

I4t Curve Shaping
This long delay time slope provides better coordination with fuses and transformer damage curves.

Short Delay and Ground Delay Zone Selective Interlocking
Provides positive selectivity on ground fault and short time protection without time delays…down to a 70 ampere breaker.

Back to top of page.


Energy Monitoring

Energy Monitoring
Energy Monitoring
Provides Data to Help Control Energy Costs

Extensive Monitoring Capabilities and Early Warning Alarms Keep the System Operating and Productive

Programmable High Load Phase and Neutral Alarm and Ground Fault Alarm
Alert the user to an impending trip condition without tripping the breaker. Monitored locally at the breaker or remotely.

Field Testing
Trip or no trip testing can be done to verify performance and operation.

Trip Event Information
Four LEDs on the trip unit are complemented by trip event information stored in the OPTIM Trip Unit memory after a trip condition. This information can be used to develop reports which analyze patterns of system alarms, system loadings, power flow, peak demand, and kWh usage.

Back to top of page.


Energy Management

Data You Can Use to Manage Energy Costs and Enhance Power Quality

Power and Energy Monitoring
of peak demand, present demand in kW, forward, reverse, and total energy in kWh.

Energy Alarming
such as 90% of peak demand exceeded.

Power Quality Monitoring
of THD and harmonic content (first through 27th) in phases A, B, C, neutral, and ground.

THD Alarming
to detect a change in power quality.

Power Factor Monitoring

Back to top of page.


System Communications and Software

Power Quality
Energy Monitoring
Provides Data to Reduce Downtime and Equipment Damage
The Cutler-Hammer IMPACC monitoring, protection, and control communications system is the most highly reliable and cost effective communications system available. From a master control PC, either on-site or off-site, the plant operator, facilities engineer, and/or maintenance personnel can monitor and/or control the entire power distribution system. Information can be made available to other PCs at different locations within a facility.

All OPTIM programming, configuration, advance warning, diagnostic, monitoring, and control capabilities can be accessed from a central PC using IMPACC Series III software. Additional IMPACC software packages include:

  • Circuit Breaker Configuration and Trip Curve Package
    that displays, configures, and coordinates time-current protection curves for OPTIM Trip Units and other devices that can be included on an IMPACC System. Multiple trip curves can be displayed on the screen to show how these devices coordinate.
  • Energy Billing Software
    (stand alone application specific package) provides capabilities to determine energy usage data by individual departments or tenants in a facility… and then creates "electric bills."
  • Waveform Capture and Harmonic Display Software
    performs a waveform capture of phase currents A, B, and C as well as neutral and ground. In addition, total harmonic distortion (THD) and individual harmonic currents of phase currents A, B, C, neutral, and ground can be displayed.

Back